Iolmaster 700. Carl Zeiss IOLMaster 700 Nava Ophthalmic The IOLMaster 700 is the first swept-source OCT-based biometer that enables OCT imaging and visualization of the entire length of the eyeball 7 Access via https://iolcon.org 8 Carl Zeiss Meditec, clinical trial, IOLMaster 700-2015-1 Technical data * Only available with Total Keratometry license ZEISS IOLMaster 700 Measurement range Axai l el ngth 14 - 38 mm Corneal radi i 5 - 11 mm Anterior chamber depth 0.7 - 8 mm
Coming soon ZEISS IOLMaster 700 with Total Keratometry from www.researchgate.net
IOLMaster 700 from ZEISS provides this planning solution with biometry measurements and three imaging reports: an OCT scan to screen for pathology and anatomical anomalies, a reference image for intraoperative guidance with ZEISS CALLISTO eye, and a SWEPT-source OCT analysis of the posterior cornea for Total Keratometry (TK) corneal astigmatism. The ZEISS IOLMaster 700 features Total Keratometry, a technology that accounts for the posterior corneal surface when making IOL power calculations, thereby replacing the assumption made by a nomogram with a precise anatomic measurement acquired via swept-source OCT
Coming soon ZEISS IOLMaster 700 with Total Keratometry
Furthermore, if a cloudy image is detected, the eye can immediately be re-measured with a subsequent B-scan Connect your ZEISS IOLMaster 700 with ZEISS VERACITY Surgery Planner to streamline your cataract workflow through the cloud Robert and Graham Barrett found that in post-myopic LASIK eyes the Barrett True K formula with TK improved the outcome predictions compared to the Barrett.
IOLMaster® 700 Fiche technique. Technical specifications of IOLMaster 700 by ZEISS ; Measurement range : Axial length 14 - 38 mm Corneal radii 5 - 10 mm Anterior chamber depth 1,5 - 6,5 mm White-to-white 8 -16 mm: Screen scale : Axial length 0,01 mm Corneal radii 0,01mm Anterior chamber depth 0,01 mm Lens thickness 0,01 mm Central corneal thickness 1 μm White-to. In some eyes, it is occasionally possible for the IOLMaster 700 to detect abnormalities of the retinal surface and.
ZEISS IOLMaster 700 SWEPT Source OCT. Axial length measurement is used not only for intraocular lens implants but also for monitoring myopia. 7 Access via https://iolcon.org 8 Carl Zeiss Meditec, clinical trial, IOLMaster 700-2015-1 Technical data * Only available with Total Keratometry license ZEISS IOLMaster 700 Measurement range Axai l el ngth 14 - 38 mm Corneal radi i 5 - 11 mm Anterior chamber depth 0.7 - 8 mm